Lippke® 4000
-
-
-
Leakage testing and Seal strength testing flexible and semi-rigid packages
-
The Package Test Systems LIPPKE® 4000 is designed for leakage and seal strength measurement on practically all types of fl exible, semi-rigid and rigid packages. The systems provide exact, definable and reproducible test conditions. The LIPPKE™ 4000 is ideally suited for direct application on the production line because it is very robust and easy to operate.
-
Advantages
-
-High flow option for porous packaging testing (i.e. Tyvek®)
-Real hole size calculation with flow sensor
-Compliance with FDA regulation 21 CFR part 11
-Validation documentation for IQ/OQ
-Easy to integrate - several interfaces are available (LAN, USB and Bluetooth)
-Package testing and oxygen analysis in one system
-Multilingual user guidance
-
Test Methods
-
-Seal Strength Test: By increasing the internal pressure of the package at a given rate to the point when the seal will burst (Burst test in compliance with ASTM F2054).
-Leakage Testing: A pre-selected pressure builds up in the package and is then held at a constant level for the required test time. The pressure loss after that time is an indication of package integrity and can be used to calculate the hole size (Pressure loss measurement and leakage testing according to ASTM F2095).
-Creep Test: A constant pressure builds up in the package. The time it takes for the seal to peel is an indication of the peelability (Creep test in compliance with ASTM F1140).
-Leak Size Determination: A pre-selected pressure builds up in the package and is then held at a constant level. The fl ow needed to keep the pressure constant is an indication of the leak size (according to the law of Hagen-Poiseuille).
-Oxygen Analysis: Determination of the residual oxygen in MAP packaging.
-
-
-
Technical data:
-
Air pressure supply: 4,0 - 8,0 bar / 60 - 120 psi
Supply Mains voltage:
100 - 250 V AC

Mains frequency:
50/60 Hz ± 1 Hz

Protection Class: IP 54
Environmental- temperatur:
+15 °C - +40 °C

RH: 0 % - 90 % non condensing
Measuring Ranges: 3 Ranges
0 ... 1.000 mbar / 0 ... 14,5 psi


0 ... 3.000 mbar / 0 ... 43,5 psi


0 ... 7.000 mbar / 0 ...101,5 psi

Resolution
0,1 mbar / 0,0015 psi


1 mbar / 0,015 psi


1 mbar / 0,015 psi

Accuracy per Measuring Range
± 0,5 mbar / 0,007 psi or 1 %*


± 2 mbar / 0,03 psi or 1 %*


± 5 mbar / 0,07 psi or 1 %*

Reproducibility per Measuring Range ± 0,5 mbar / 0,007 psi or 1 %*

± 2 mbar / 0,03 psi or 1 %*

± 5 mbar / 0,07 psi or 1 %*



* whichever is greater
Standards ASTM F1140

ASTM F2054

ASTM F2095

ASTM F2096
-
-
-
Manufacturer: Your contact:
-
-
- - Peter Schlösser
Productmanager

+49 2631 / 3933-13
E-Mail
-
-
-
Accessories:
-
foot switches
With these food switches you can control the instrument easily.
PPC300
Plate assembly for limiting package expansion
-
Produktbild
-
- - -
Lippke® 4000
-
» download brochure «
-
» Get more product information «
-
» print page «
-
-
-
leaflet     -    
Permatran-W 1/50
WVTR Transmission Rate Testing System

AB PLUS
Desktop weighing and sorting system for tablets, capsules and other small parts

Mixer Torque Rheometer MTR
Measuring quantitatively and analysing the consistency of wet mass for research, development and quality control

Mini Coater / Drier MCD-2
Bench-top Tablet and Spheroid Coater / Drier MCD-2

PERMATRAN-C ® 4/41
Carbon Dioxide Permeation Rate Measurement Systems

OX-TRAN ® 2/21
Oxygen Permeation Rate Testing

Extruder 40
Production Gear Extruder